Tekmar 314

The tekmarNet 2 wiring center 314 is designed to provide a zoning solution for heating systems. It can be used in applications ranging from baseboard zones, to radiant heating zones. This product provides power for up to four tekmarNet 2 thermostats and up to four 115 VAC zones pump outputs, as well as providing an end switch closure to enable an external device such as a boiler. An outdoor sensor input is included and provides the outdoor air temperature reading on each thermostat when an optional outdoor sensor is installed.


  • Finish Blue
  • UPC 779655031401
  • Online Product ID 9574641
  • Width 5.5"
  • Height 5.5"
  • Depth 2.25"
  • Warranty 3 years Limited
  • Prop65 Warning Warning: This product can expose you to chemicals including lead which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Ambient Temperature Range 32 to 122 degree F
  • Class Class 2
  • Control Type Microprocessor
  • Enclosure Material Abs,Polycarbonate
  • Indoor Outdoor Indoor
  • Nema Rating NEMA 1
  • Power Rating 3 VA Minimum, 11 VA Maximum
  • Power Supply 24 VAC plus /-10 percent , 60 Hz
  • Relative Humidity <=90 percent Non-Condensing
  • Relay End Switch Relay: 24 VAC, 2 A, Zone Group Pump Relay: 115 VAC, 5 A
  • Safetylist CSA C US, Meets Class B: ICES and FCC Part 15
  • Sensor NTC Thermistor, 10 kOhm at 77 degree F (25 degree C plus /- 0.2 degree C) Beta = 3892, Humidity Sensor: 0 to 90 percent plus /- 3 percent RH
  • Suitable For Use With tekmarNet 2 Thermostats
  • Shipping  1.4 lbs.

Additional information

  • tN4 expansion terminals
  • Outdoor sensor input
  • Isolated end switch
  • Supports two-stage tekmarNet 2 thermostats
  • For use with tekmarNet 2 thermostats only
  • External diagnostic LEDs
  • Four 115 VAC powered pump outputs
  • CSA C US approved for use in USA and Canada
  • Only requires 2 wires per zone